For CE release notes and other features in 2-3-0-0 click here
Based on feedback from our customers, we have provided the ability to print an A4 confirmation sheet with much the same information that will be printed on the narrow labels.
Once you have printed the narrow CE Marking labels, you may want to print off the A4 confirmation pages again at a later date. This is easily done by setting up a report from within the Report Manager in the usual way to enable printing of the confirmation pages.
Standard paragraphs that you are able to add via [File - Properties - Standard Paragraphs] are now available for use on the 'Job Details Page' for the 'Discount%' and 'Deposit' pages.
Right click in the 'Discount%' or 'Deposit' text box to reveal the popup menu. From the menu, you are now able to select the previously saved 'Standard Paragraphs'.
This option has now been enhanced in all required modules.
For a direct glazed window frame with either the head jambs or cill that had a width less than 30mm the U-value calculation would fail, and you would be unaware what component/s it was failing on.
With this fix: Clicking in the 'Frame section error' button will now tell you the component the U-Value calculation failed on. There may be more than one component causing the error, but it will only display one component at a time. Once the component width has been increased, the U-Value calculation will be repeated and further components found to be in error will be displayed. This continues until all components widths have been increased to meet the specifications defined in EN10077 part 1 Annex D3.
This error has now been fixed for the sliding sash window module.